Many details need to be considered in the design of steel structure buildings, such as appropriate structural damping ratio, rigid column base design, beam column rigid connection design, floor design, etc. The details of steel structure architectural design are discussed in detail.

1. Suitable structural damping ratio

In the overall calculation of steel structure building, especially according to the requirements of seismic code, it is very necessary to choose the appropriate structural damping ratio. Unless otherwise specified, the damping ratio of building structure should be 0.05. Because different steel structures have different seismic influence coefficients, the selection of damping ratio should be based on the proportion of materials. Generally speaking, the more flexible the overall stiffness of the structure, the lower the damping ratio.

2. Rigid column base design

The commonly used column bases of steel structure buildings are embedded type, external type and exposed type, and the exposed type is more convenient for on-site installation and positioning. It should be noted that the stiffness of the column base is realized by the elastic or plastic deformation of the base plate. Therefore, in the design, it should be considered that the limit value of the story drift angle should have a certain margin, and the bending moment at the top of the column caused by the downward movement of the bending moment reacts on the bending point of the bottom steel column.

3. Floor design

Steel structure building has precast floor, cast-in-place floor, composite floor and so on. If precast slabs are used, floor joint cracking due to temperature variation and load distribution should be considered. In addition, in the floor design, attention should be paid to avoid one-way centralized layout, and try to form a two-way load-bearing structure.

4. Beam column rigid connection design.

Conventional design method or full section bending design method can be used to calculate the beam column rigid connection in steel structure buildings. When the bending capacity of steel beam flange is more than 70% of the total section capacity, the conventional design method can be used. If it is less than 70%, full section bending design method shall be adopted.

There are many factors to be considered in the design of steel structure buildings, and each link is very important.

Copyright:佛山市勝邦鋼結構有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號
主站蜘蛛池模板: 在线看a级片| 青操在线| 91久久国产口精品久久久久| 男男gaygays18| 久99频这里只精品23热 视频| 美女被羞羞产奶动漫| 可以免费看黄的网址| 777欧美午夜精品影院| 亚洲在线视频一区| 轻点好疼好大好爽视频| 免费在线观看的视频| 综合7799亚洲伊人爱爱网| 暖暖高清视频在线观看日本| 男人戴避孕套桶女人视频| 乱码卡一卡二卡新区在线| 青青草国产精品欧美成人| 谷原希美jux865在线观看| 日本一视频一区视频二区| aaa级精品久久久国产片| 制服丝袜在线一区| 成年网站在线在免费播放| 美女尿口18以下禁止观看免费| 在线观看免费日本| 啊用力太猛了啊好深视频免费| xxx国产精品视频| 日本人69视频jzzij| 久99久热只有精品国产99| 有人在线视频免费观看| 91探花国产综合在线精品| 男人网站在线观看| 日本视频在线观看免费| 麻豆网址在线观看| 2017亚洲男人天堂| 99视频免费看| 青青热在线精品视频免费| 99re这里只有精品99| 女仆放荡勾人h嗯啊| 99热久久这里只精品| 一念永恒87在线观看全集免费播放| 久久久久久久综合狠狠综合| 色老板在线看|